數個城市為煤氣熱水器換為熱泵電熱水器提供資助但名額有限,例如San Jose附帶配電盤升級資助,這是該市為2035年全麵放棄煤氣的計劃之一部。

Heat pump water heater or HPWH,類似空調製熱或即熱泵,機器循環是:R134壓縮為汽態--冷凝為液態放熱--蒸發為汽態吸熱。冷凝器在桶中,蒸發器壓縮機在上部,上部風扇抽取環境熱空氣,側麵出風溫度約低3F,環境溫度要求為40-90F,加州很適合。如果環境溫度低或空間不夠大(至少1000cuft),可加Duct保證抽取的空氣不太冷。通常,熱泵態耗電500W(Rheem說350W),電熱線圈是5KW和2.25KW(不同時工作),熱泵態每天耗電不過兩度,電熱態可以是好幾倍。

1. General

Parts store: 

Graybar, 2201 Ringwood Ave, San JoseCA 95131 408-964-2100132418 splice box

Herning Underground Supply a WESCO Company 2800 Mead Ave Santa Clara, CA 95051, (408) 562-0400, (408) 562-0448, 

Consolidated Parts - 2425 Scott Blvd, Santa Clara, CA wire and splice box connectors

Buckles-Smith Electric - 540 Martin Ave, Santa Clara, CA , larger

NEC: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=70

load calculation: https://www.ladbs.org/docs/default-source/forms/inspection-forms/sfd-electrical-vehicle-charger-service-load-calculation-form-in-form-00.pdf https://www.nachi.org/bbsystem/viewtopic.php?t=16685

contractor: Formosa elec corp, 6745 Normandy Dr, Newark, CA 94560, (510) 709-5978; Roland Marcelo 510 714 5137, 菲律賓人  30664 Granger Ave, Union City, 輻射全灣區

http://wechatcontractors.blogspot.com/p/blog-page.html

 

1.1 Panel & AFCI

新表之一 Eaton MBE4040B200BTS 22x34.38x5.38",BR類Breaker。但Eaton隻有load center可用plug-on breaker。相應AFCI+BGC在ebay上I比較便宜。

新表之二 SquareD的SC3042M200PS 21.5x32.12x6.3" 57.1Lbs孔距16x32.56" 則是plug-on和solar ready。所謂plug-on就是AFCI breaker的尾卡可以插在零線螺絲座上省去pigtail。Hom115/120PDF(AFCI+GFCI)故障率高,但升級可不用AFCI。SC2040M200PS 21.5x29.37x6.3" 孔距116x30.24" 52.8Lbs

Solar ready就是可在200A開關前接逆變器AC的240V25A(要附加兩個接線座Zoro G1325046不過$1,原裝SR69064A賣$80)。Conduit 2",線為2/0銅線,地線#4,bonding#6。

新表之三 SquareD的SQ2040VP value pack 43.1Lbs https://images.homedepot-static.com/catalog/pdfImages/28/28955bff-4708-41f4-bb56-6d906f4ba10f.pdf

順便說主斷路器也會在過載時切斷,但多半是在浪湧或雷擊時。複位前應關閉各支路斷路器並避免直視。家用額度是80%即200A對連續負載是180A,或者計算負載時,連續負載要乘以1.25。在額定負載下斷路器可能要1千秒才切斷。

AFCI:舊支路若未改或延長在6'以內,則無需加裝;否則所有15-20A支路都需裝:https://forums.mikeholt.com/forum/active-forums/nec/143621-panel-change-arc-fault-requirements

實例:https://www.youtube.com/watch?v=jcbpIfvNI_M 其中鋁線上抹了防腐蝕脂Noalox Anti-Oxidant Sunnyvale:https://ecityhall.sunnyvale.ca.gov/cd/i_Electrical.aspx SanJose:https://www.sanjoseca.gov/home/showdocument?id=25985 https://www.sanjoseca.gov/home/showdocument?id=25985 用紅黑線供電的雙120V需用2-pole breaker,除埋地銅棍外要#6銅線接水管。雙銅棍或單銅棍但帶接地25歐內測量報告。接地電阻測量:https://www.baselinesystems.com/mediafiles/pdf/62_percent_test_instructions.pdf Neutral線徑:http://www.sitemason.com/files/oVJtny/200%20AMP%20RESIDENTIAL%20HOME%20SERVICE%20ENTRANCE%20REQUIREMENTS.pdf https://www.ecmweb.com/national-electrical-code/code-basics/article/20890526/characteristics-of-the-neutral-conductor

1.2 PG&E

PG&E承諾5天回複: https://www3.pge.com/ccoweb/#/login https://www.pge.com/ccoweb/customer.portal?_nfpb=true&_nfls=false&_st=&_pageLabel=MyApplications 注冊登錄後按部就班,要city permit號並上傳site plan:https://www.pge.com/includes/docs/pdfs/mybusiness/customerservice/startstop/newconstruction/processguide/processguide.pdf

https://www.pge.com/includes/docs/pdfs/mybusiness/customerservice/startstop/newconstruction/greenbook/servicerequirements/greenbook_manual_full.pdf

Conduit calculator:https://www.southwire.com/calculator-conduit NEC建議填充比為單線53,三線以上40%。

PVC管可用於室內外,1/2管烤彎需加熱4分鍾以上。EMT鐵管在室外需用rain tight接頭。Wire gauge: https://www.usawire-cable.com/pdfs/NEC%20AMPACITIES.pdf 4/0鋁線205A@90C,2/0銅線195A@90C,#2/3為130/115A,#8/10/12取40/30/20A。

PG&E要求: 離地至少12',通信線再高1',拉繩離屋頂1',表心高48-75"最佳66",離窗3'離拐角10"。地埋要求如下:https://www.pge.com/includes/docs/pdfs/shared/customerservice/otherrequests/newcontruction/BRSC_Guide_Trenching.pdf https://www.pge.com/includes/docs/pdfs/mybusiness/customerservice/startstop/newconstruction/greenbook/servicerequirements/062288.pdf http://www.siliconvalleypower.com/home/showdocument?id=11073

挖坑後鋪PG&E要求的沙,然後用Jumping Jack拍實:https://www.homedepot.com/tool-truck-rental/Jumping-Jack/5200000642/ 人行道要鋪膠合板,車道要鋼板蓋住。

擴裝新表時的步驟是:PG&E斷電、用戶裝新表、city檢查通過、PG&E上電。通常PG&E和city下來都是4小時窗口,新表若換位可安排在同一天。

擴裝200A地埋管要多幾步:申請PG&E交$1500押金,同時聯係USA確定現有電氣通信管道位置;PG&E下來看並交付設計文檔;簽約文檔後找承包商;挖溝鋪沙和3"PVC管道後(水平彎頭半徑36"垂直彎頭24"),PG&E第一次檢查,然後承包商覆土;PG&E第二次下來,先用Mandrel和Pulling tape(M560154)如同洗瓶子的刷子和fish wire走管一遍保證無堵,再穿4/0鋁線及1/0零線;然後是city檢查通過;PG&E第三次下來通電。如果是400A,管道4",線750及零線4/0,彎頭36"。

Trench即挖溝最小是12"寬30"深,底部2.5"沙然後是3"管,管上6"沙然後是填土,由管上部到地麵高度至少24"。同一溝裏可以放通信管道,煤氣管道隔開至少12"。通常靠近房子處有13x24x18"H splice box,便於維修並可解決彎管問題。

132418 splice box Christy box: https://oldcastleinfrastructure.com/brands/christy/ 

040933(13x24x18"):https://www.platt.com/platt-electric-supply/Pull-Boxes-Concrete-Rectangular/Oldcastle-Precast/17301726/product.aspx?zpid=1204456 

1.3 Sense power monitor

https://www.youtube.com/watch?v=Zevh7viz5ts sense monitor帶Solar的多兩個鉗型電流傳感器價格$350,手機App控製可自動分辨設備但不大準。用於熱水器時接solar的改接熱水器電源,這樣同時監控全房和熱水器耗電。該機用240VAC供電,傳感器需同相,例如有Sense標簽麵都背向配電盤,wifi天線可借用配電盤下端空餘的1/2"孔插入其中。SN: N928000192

2. Water heater

2.1 Surround parts

thermostatic mixing valvehttps://www.supplyhouse.com/Honeywell-Sparco-AMX302TLF-Lead-Free-DirectConnect-Water-Heater-Kit-Includes-3-4-ASSE-1017-Mixing-Valve-3-4-Cold-Water-Tee-11-Flexible-SS-Connector 按下可調溫,混水前的熱水溫度通常設為145-150F可增加10gal可用熱水。原理:https://www.youtube.com/watch?v=aE6SSnRcqcE 熱水器可設為159F=65C,調溫輸出117F=47C。

Condensation pump: 用於將水抽高去洗衣機下水管。可配check valve:https://www.amazon.com/VCMX-20ULST-Automatic-Condensate-Removal-horsepower/dp/B002MGYF3S https://littlegiant.com/media/231524/998124_vcma_intl_web.pdf 有3個1-1/8"口可插入45度切角的3/4 PVC管,另有1/4" Barb,輸出為3/8 Barb"可加check valve。側麵有小卡片頭必須取出。

Econet wifi module: REWRA631EWH網說可用,下載app注冊登錄。客服:800.255.2388, 

Expansion tank: 2gal tank用於50-80gal熱水器。https://www.plumbingsupply.com/thermal-expansion-tanks.html

Vacuum relief valve: https://plumbingperspective.com/faq-basic-components-in-a-hot-water-system 

2.2 Heatpump

https://contractors.efficiencyvermont.com/Media/Default/docs/programs/efficiency-vermont-heat-pump-water-heater-installation-guide.pdf 適合室溫45-110F,太最好50F以上,空間至少750sqft不然要管道。外加themostatic mixing valve可將熱水器水溫提至140F,這樣使用電加熱原件的機會更少。

常規40gal Rheem D21.75x51.5" 重165Lbs,XE50T10HD50U1 D22.25x61",178Lbs,5KW。

2.2.1 Rheem

上端接線盒和濾網(俯視圖中直線),接口都在側麵。過壓泄放口,冷凝水出口均為3/4 FPT高39-1/2",冷凝水溢出為1/4"出廠是擰死的,冷熱水3/4 MPT在側麵一低一高,兩者均應加關斷閥因為要用恒溫混水閥,冷水入口推薦thermal expansion tank。Thermalstatic mixing valve套件AMX302TLF是按傳統熱水器設計的,冷熱水口間隔約11-1/4"。此外原裝漏水感應器插好線粘在底水盤上。內置wifi可用手機 app,如果要通過互聯網控製需加Econet kit粘在桶的側麵。

冷水入口的Expansion vavle似可用Relief valve代替:https://www.walmart.com/ip/WATTS-530-3-4-Adjustable-Relief-Valve-3-4-x-1-2-175psi/161435627 並建議加vacuum relief valve:https://www.homedepot.com/p/Eastman-3-4-in-MIP-Vacuum-Relief-Valve-60158/300702610 Zoro 6AYW3 1/2 F-F-MNPT Tee

2.2.2 安裝 https://www.youtube.com/watch?v=n0RCjiNa95k https://www.youtube.com/watch?v=JrMpdSQ2WGg

強烈建議原泡沫底座保留放在水盤中以免水盤的水腐蝕熱水器底麵,這樣condesation冷凝水和泄壓水均可導入水盤。不然的話,冷凝水可以導入水盤外部的水管,例如用1/2軟管插在洗衣機下水管中。

1. 冷熱水去熱水器:原接口若非3/4MIP需要改正,若冷熱水無關斷閥需要都加上,且間距不超過11吋;2.加上述混水閥,注意混水閥有1/2 female口可接Relief/Vaccum valve;3.混水閥輸出的3/4MIP用Push to Connect Push x Female 90-Degree或3/4 in. Brass PEX Barb x 3/4 in. Female轉為Pex接頭;4. pex管及上述轉3/4FIP接熱水器。5.泄壓閥及冷凝水出口均為3/4接PVC去底部水盤,水盤去drain。注意冷水關斷閥需要在混水閥前,不然冷水會通過混水閥串入熱水管,維修時必須關斷總閥。

更新:上麵的安裝是將混水閥倒轉,這裏是正裝方式。熱水器上平麵有4x3/4"自攻螺絲,改其中兩個為2x1-1/2"固定一塊1x6x18.25"板作為基板。原接大桶的軟管鬆開後上麵是FPT(=FIP=NPT-F)接混水閥套件AMX302TLF的上端MPT,混水閥下端是FPT接MPT-PEX 90度,固定在基板上。PEX水平去桶邊緣接PEX90deg和PEX-T下接PEX管,分別經PEX-FPT90deg接熱水器MPT口。PEX-T朝上的一端經PEX管及PEX-1/2FIP頭接Vaccum relief valve。熱水器輸出PEX可切斷串聯PEX接頭的球閥,原冷水入口的關斷閥保留。過壓溢出和冷凝水各用3/4彎頭印至水盤,冷凝水溢出口買來時是塞住的保留。

裝後緩慢打開注水閥並檢查有無漏水,再打開各熱水龍頭放氣直至出水無空氣,爾後才才可加電。按幾下mode圖標選heat pump mode,耗電最大600W;但因水溫低會自動打開電加熱,此時耗電5.7KW,2-3小時就有熱水。檢查水溫按Status圖標再按sensors。

2.3 AO Smith  HP10-50H45DV

4.5KW+700W,D22x63",196Lbs,沒有wifi。Install:https://www.youtube.com/watch?v=YeMqq5T2dCQ 冷水入口有Vacuum relief valve。關斷閥靠近熱水器在混水閥後,因此還要一個冷水端輸入閥。冷凝水用量更1/2" PVC。接線盒裏還有#18線,切斷後接冷凝水泵的溢出切斷開關,如果冷凝水泵不排水浮子開關接通將會切斷熱泵並顯示"CONDENSATE DRAIN ALARM"。

2.4 Solar water heating

有PV板後原來的太陽能熱水器有點過時,國內最常見的真空管占地小,但在美國也是$1600以上。

3. San Jose

city: 2019 152443 RS,535-3555, 7-8am 29th; Infoinspector@sanjoseca.gov; Voicemail: 408-535-7641

PGE: 118236835, 18777437782 Sarah, 559-347-5066 Nyson Thao, 8-12 28th off, 8-12 29th on

https://www.sanjoseca.gov/your-government/departments-offices/environmental-services/climate-smart-san-jos/electrify-san-jos

heatpump $2000,service panel $2500.  4377.59+

city在線申請:https://sjpermits.org/permits/ssl/sa_receipt.asp 首先注冊要輸入地址(街名一行,另一行選後綴如Ave)和parcel#(可由網上找);登錄後選申請permit進入step1後顯示地址,要點擊地址才進入下一步;然後項目類型隻有roof和sub trade,選單項後才顯示各項目列表及數量,我是升級配電盤換熱水器,故輸入了兩個1;然後是簽字及付款。完後有inspection鏈接但目前失效。

https://sjpermits.org/permits/ 點擊Apply for an online permit, 輸入用戶/口令,點擊Check app and status,點擊文件號即permit#,點擊Job card打印備檢查員簽字。必須安裝並簽好火警和一氧化碳報警器的文檔,注意合法產品。每個臥室和臥室外區域/每層需火警,臥室外區域需一氧化碳報警器。

舊表12.5x19.75x4.625"底高44.75",左/右空19"/8"至屋頂51.5"屋頂上26.5" 管1.5"長80"。右側孔高46.25"用1"管60A往上去廚房;下有1/2" 20A和3/4" 60A管貼地,前者穿過磚牆去前車庫,後者走車庫上去spa;內有20A數組入牆去附近的外牆開口箱體。新盤螺絲孔16x32.69",孔距邊緣2.8"。

步驟:1)因有入牆孔需底高不變,新盤SC3042M200PS,上午開始自己或PG&E直接剪斷入線再包起裸露線頭,拔出舊表剪斷舊線,拆掉舊管和配電盤。2)為利用舊牆孔和側線管,以其為基準定位,有偏時牆孔外緣可擴大或改側線管長短。先鑽上方兩孔掛起新panel再量。下端線管高度相差不大可直接利用改牆夾位置。3)我預先將spa 60A線改作熱水器,不好,因60A線很難接30A breaker/插座。最好是重布用1-1/4單管去車庫125A子板,預留給ADU。125A線長約64'。City inspection和PG&E加電約在同一天下午錯開半小時。4)Breaker與Panel須同廠牌,紅黑線需接20pole breaker。200A用2/0

銅線,地線#4需兩根,接地5/8x8'銅棍和金屬水管。

Heatpump安裝: 原冷水端有球閥,鐵管3/4 MPT接24"半硬管接熱水器。可換為Amazon的3/4 MPT-FPT球閥2個,經3/4 FPT-FPT軟管,接混水閥套件AMX302TLF,混水閥下端接MPT-PEX,PEX管水平去桶邊緣接PEX90deg和PEX-T再接PEX管,分別經PEX-FPT90deg接熱水器MPT口。PEX-T朝上的一端經PEX管及PEX-1/2FIP頭接Vaccum relief valve。更新:利用原半硬管換膠墊,未用混水閥和expansion tank,有vaccum relief valve,大桶上端換兩長螺絲固定木板上裝3/4 MPT接頭以便用傳統接法。注水一夜後發現浴室sink和廚房水龍頭冷熱水均無,原來是出水喉頭Aerator堵塞。heatpump mode一夜後即由64F上升到120F,改mode是反複按此觸摸鍵直至所選。提醒:換熱水器打開各龍頭時要緩慢以防堵塞。

4. Saratoga

https://www.svcleanenergy.org/water-heating/  https://www.svcleanenergy.org/wp-content/uploads/2019/11/Reservation-Tracker-Public-Update-2019.11.19.pdf

heatpump $2000,sense monitor $300;smart performance package $1500,service panel $2500. FFHP-0118

地埋由電線杆至廚房外新配電盤220',3"管由PG&E提供4/0鋁線。舊盤及電線可以不動。新盤用2/0-3和#4線長20'接去地下室200A子板。新盤先裝好通過city驗收在讓PG&E通電。新盤靠後院便於將來引出125A給ADU。

Heatpump安裝: 切斷原半硬管,原有一個球閥保留;加push-to-connect兩軟管其一球閥;接混水閥套件AMX302TLF,混水閥下端接MPT-PEX,PEX管水平去桶邊緣接PEX90deg和PEX-T再接PEX管,分別經PEX-FPT90deg接熱水器MPT口。PEX-T朝上的一端經PEX管及PEX-1/2FIP頭接Vaccum relief valve。

5. Newark

http://www.newark.org/departments/human-resources/employee-directory https://www.newark.org/departments/green-newark/energy-upgrade-ca

不能網上申請但可FAX,見本頁https://www.newark.org/departments/public-works/building-inspection-division中additional iinformation的文檔。

煤氣熱水器換新的較高效率的有$400,電熱水器換heat pump有$1500。650-226-4010

6. Supplier

Electric Distribution Co. 1135 Auzerais Ave, San Jose, CA 95126, (408) 293-5818 https://www.edgesgroup.com/manufacturers 7-4:30pm

Herning Underground 2800 Mead Ave Santa Clara, CA 95051, (408) 562-0400, (408) 562-0448 www.herningunderground.com  7-5pm

C10 license: https://www.peerlessinstitute.com/how-to-become-a-c10-electrical-licensed-contractor/ https://www.contractorresource.com/california-contractors-exam-study-guide-electrical-c-10

B2:

SJ salary: https://www.sanjoseca.gov/Home/ShowDocument?id=45529

7. Maintenance 1-800-995-0982

https://www.youtube.com/watch?v=EP1G9kpX_UU  https://www.reddit.com/r/Plumbing/comments/qwf3zq/rheem_hybrid_water_heater_and_error_code_a005 https://www.youtube.com/watch?v=R1qFsETirJ4 

Thermostat: 以filte為水平線其上方有,DT-Discharge Temp - blue at lower left,  AT - ambient temp - top, ST - Suction Temp - yellow right middle, ET - Evap Temp - grey right bottom. 同時按Mode+Next進診斷模式。

[ 打印 ]